| Category | Analytical instruments |
| Type | others |
| Software | No software |
| Length x width x height | 700.0 × 700.0 × 450.0 |
| Weight | 25 kg |
| worked hours | |
| hours under power | |
| state | good |
| At local norms | --------- |
| status | visible |
| Last availability date | 26/11/2026 |
| Product id | P261120109 |
| Language |
THERMO SCIENTIFIC KINGFISHER FLEX 24 DNA purification instrument, type 711, supplied with a Flex 24 deep-well head. The stated year of manufacture is 2010.
The instrument powers on and its screen is reported to be working. Rotation was tested and reported as OK, and the head was tested raising and lowering and reported as OK. The equipment has not been tested in its intended function, so its performance for DNA purification has not been confirmed. No software and no computer are included.
Rust marks are reported on the paintwork. Please take this cosmetic condition into account when assessing the equipment.
This listing is for the Thermo Scientific KingFisher Flex 24 instrument and the stated Flex 24 deep-well head. The available description does not specify any additional accessories, consumables, software, computer, or other components, so these should not be assumed to be included. The condition information is limited to the power-on, screen, rotation, and head movement checks described above; no further operational claims are made. In particular, the reported checks do not establish that the instrument completes a purification process or that it is ready for use. Please review the stated configuration and condition carefully before purchase.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
THERMO SCIENTIFIC KINGFISHER FLEX 24 DNA purification instrument - type 711
Year of manufacture: 2010
Flex 24 deep-well head
type 711
No software
No computer
Equipment powers on
Screen working
Rotation test OK
Head raising and lowering test OK
Equipment not tested in its intended function
Rust marks on the paintwork - see photos
Description provided by the seller (translated automatically). We recommend organizing a visit or a video call to confirm the details before you buy.
| Client type | Machinery dealer |
| Active since | 2018 |
| Offers online | 104 |
| Last activity | Nov. 26, 2026 |
THERMO SCIENTIFIC KINGFISHER FLEX 24 DNA purification instrument - type 711
Year of manufacture: 2010
Flex 24 deep-well head
type 711
No software
No computer
Equipment powers on
Screen working
Rotation test OK
Head raising and lowering test OK
Equipment not tested in its intended function
Rust marks on the paintwork - see photos
Description provided by the seller (translated automatically). We recommend organizing a visit or a video call to confirm the details before you buy.
| Category | Analytical instruments |
| Type | others |
| Software | No software |
| Length x width x height | 700.0 × 700.0 × 450.0 |
| Weight | 25 kg |
| worked hours | |
| hours under power | |
| state | good |
| At local norms | --------- |
| status | visible |
| Last availability date | 26/11/2026 |
| Product id | P261120109 |
| Language |
THERMO SCIENTIFIC KINGFISHER FLEX 24 DNA purification instrument, type 711, supplied with a Flex 24 deep-well head. The stated year of manufacture is 2010.
The instrument powers on and its screen is reported to be working. Rotation was tested and reported as OK, and the head was tested raising and lowering and reported as OK. The equipment has not been tested in its intended function, so its performance for DNA purification has not been confirmed. No software and no computer are included.
Rust marks are reported on the paintwork. Please take this cosmetic condition into account when assessing the equipment.
This listing is for the Thermo Scientific KingFisher Flex 24 instrument and the stated Flex 24 deep-well head. The available description does not specify any additional accessories, consumables, software, computer, or other components, so these should not be assumed to be included. The condition information is limited to the power-on, screen, rotation, and head movement checks described above; no further operational claims are made. In particular, the reported checks do not establish that the instrument completes a purification process or that it is ready for use. Please review the stated configuration and condition carefully before purchase.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
| Client type | Machinery dealer |
| Active since | 2018 |
| Offers online | 104 |
| Last activity | Nov. 26, 2026 |