This large-capacity autoclave, manufactured by INOXTORRES, model 17.700 L, is designed for industrial applications requiring precise pressure and temperature control. It features a horizontal cylindrical chamber with a volume of 17,700 liters and a diameter of 2,500 mm. The autoclave operates at a design pressure of 9 bar and a design temperature of 30°C, utilizing air as the working fluid.
Constructed from robust S-275-JR steel, the autoclave body has an 8 mm thickness, with 15 mm thick torispherical Klopper-type ends. It meets the PED 2014/68/EU IV Module G classification standards, ensuring compliance with relevant safety and quality regulations.
The unit includes a hydraulic-driven tongue-and-groove door closure system, equipped with a large wheel handle for secure opening and closing. The door features locking mechanisms and is supported by cables or ropes for added security. The autoclave is mounted on sturdy support legs that keep it elevated from the ground.
A control and pressure gauge is attached on top of the door for monitoring purposes. The hydraulic or mechanical drive unit is positioned on the left side of the autoclave and is partially covered with a protective plastic sheet. Bolted flanges and fittings are visible on the side, facilitating connections and maintenance.
The autoclave's exterior is painted in a smooth, glossy dark blue finish, showing no visible signs of rust, dents, or corrosion, indicating well-maintained condition. Cables and hoses are attached near the door area, supporting operational functions.
This equipment is designed with precision adjustment systems for door alignment and integrated safety features, including a safety valve set to 9 bar and provisions for pressure switch and solenoid valve interconnections. Preventive maintenance has been performed in accordance with the original instruction manual, including the use of high-quality gaskets and periodic inspection of mechanical components to prevent wear.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
A high-capacity autoclave manufactured by Instalaciones Inoxtorres S.L. is now available for sale. It is designed for industrial processes that require precision and safety. This unit stands out for its robust steel construction and hydraulic drive system.
1. Main Technical Specifications
Capacity and Dimensions:
- Total volume: 17,700 liters.
- Diameter: 2,500 mm.
- Body length: 3,000 mm.
Operating Performance:
- Design pressure: 9 bar g.
- Test pressure: 12.87 bar g.
- Design temperature: 30°C.
- Working fluid: Air.
Construction:
- Material: S-275-JR steel.
- Thicknesses: 8 mm body and 15 mm torispherical bottoms (Klopper type).
- Standards: Classification per PED 2014/68/EU IV Module G.
2. Key Features and Safety
- Closing System: Tongue-and-groove door operated by hydraulic cylinders for rotation and closure, ensuring a tight
and secure seal.
- Precision Adjustment: The unit features front (handwheel), vertical (base screws), and tilt (eccentric shafts) adjustment systems for
perfect door alignment.
- Integrated Safety: Includes a safety valve set to 9 bar and systems designed for the interconnection of pressure switches and shut-off solenoid valves.
3. Condition and Maintenance
The equipment has been operated in strict accordance with the original instruction manual.
Key preventive maintenance tasks have been performed, such as:
- Use of high-quality gaskets (U-shaped profile, HL1053B by MEREFSA).
- Periodic inspection of bronze bushings and mechanical components to prevent
excessive wear.
Description provided by the seller (translated automatically). We recommend organizing a visit or a video call to confirm the details before you buy.
What is the operating temperature of this equipment?
This equipment has a working temperature of 30°C.
What is the working pressure range of this equipment?
This equipment has a working pressure range of -1 to +9 bar.
What is the test pressure of this equipment?
This equipment has a test pressure of 12.87 bar.
The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
| Client type | Factory – small or medium company |
| Active since | 2023 |
| Offers online | 1 |
| Last activity | Nov. 4, 2026 |
A high-capacity autoclave manufactured by Instalaciones Inoxtorres S.L. is now available for sale. It is designed for industrial processes that require precision and safety. This unit stands out for its robust steel construction and hydraulic drive system.
1. Main Technical Specifications
Capacity and Dimensions:
- Total volume: 17,700 liters.
- Diameter: 2,500 mm.
- Body length: 3,000 mm.
Operating Performance:
- Design pressure: 9 bar g.
- Test pressure: 12.87 bar g.
- Design temperature: 30°C.
- Working fluid: Air.
Construction:
- Material: S-275-JR steel.
- Thicknesses: 8 mm body and 15 mm torispherical bottoms (Klopper type).
- Standards: Classification per PED 2014/68/EU IV Module G.
2. Key Features and Safety
- Closing System: Tongue-and-groove door operated by hydraulic cylinders for rotation and closure, ensuring a tight
and secure seal.
- Precision Adjustment: The unit features front (handwheel), vertical (base screws), and tilt (eccentric shafts) adjustment systems for
perfect door alignment.
- Integrated Safety: Includes a safety valve set to 9 bar and systems designed for the interconnection of pressure switches and shut-off solenoid valves.
3. Condition and Maintenance
The equipment has been operated in strict accordance with the original instruction manual.
Key preventive maintenance tasks have been performed, such as:
- Use of high-quality gaskets (U-shaped profile, HL1053B by MEREFSA).
- Periodic inspection of bronze bushings and mechanical components to prevent
excessive wear.
Description provided by the seller (translated automatically). We recommend organizing a visit or a video call to confirm the details before you buy.
What is the operating temperature of this equipment?
This equipment has a working temperature of 30°C.
What is the working pressure range of this equipment?
This equipment has a working pressure range of -1 to +9 bar.
What is the test pressure of this equipment?
This equipment has a test pressure of 12.87 bar.
The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
| Category | Industrial autoclaves / drying stoves |
| Chamber volume | 17700 L |
| Operating t° | 30 °C |
| Pressure | 9 bar |
| Chamber Ø | 2500 mm |
| worked hours | |
| hours under power | |
| state | as-is, where-is |
| At local norms | yes |
| status | |
| Last availability date | 28/10/2026 |
| Product id | P260324163 |
| Language |
This large-capacity autoclave, manufactured by INOXTORRES, model 17.700 L, is designed for industrial applications requiring precise pressure and temperature control. It features a horizontal cylindrical chamber with a volume of 17,700 liters and a diameter of 2,500 mm. The autoclave operates at a design pressure of 9 bar and a design temperature of 30°C, utilizing air as the working fluid.
Constructed from robust S-275-JR steel, the autoclave body has an 8 mm thickness, with 15 mm thick torispherical Klopper-type ends. It meets the PED 2014/68/EU IV Module G classification standards, ensuring compliance with relevant safety and quality regulations.
The unit includes a hydraulic-driven tongue-and-groove door closure system, equipped with a large wheel handle for secure opening and closing. The door features locking mechanisms and is supported by cables or ropes for added security. The autoclave is mounted on sturdy support legs that keep it elevated from the ground.
A control and pressure gauge is attached on top of the door for monitoring purposes. The hydraulic or mechanical drive unit is positioned on the left side of the autoclave and is partially covered with a protective plastic sheet. Bolted flanges and fittings are visible on the side, facilitating connections and maintenance.
The autoclave's exterior is painted in a smooth, glossy dark blue finish, showing no visible signs of rust, dents, or corrosion, indicating well-maintained condition. Cables and hoses are attached near the door area, supporting operational functions.
This equipment is designed with precision adjustment systems for door alignment and integrated safety features, including a safety valve set to 9 bar and provisions for pressure switch and solenoid valve interconnections. Preventive maintenance has been performed in accordance with the original instruction manual, including the use of high-quality gaskets and periodic inspection of mechanical components to prevent wear.