Becton Dickinson BD FACSCanto II flow cytometer

7,000 € Price is negotiable

Make an offer
  • - Secured payment for the purchase
  • - Dedicated compliance check of the seller
  • - Logistics and customs support if applicable
  • - After-sale follow up if needed

Contact us to receive an offer.

Manufacturer Becton Dickinson
Model BD FACSCanto II Flow Cytometer
Year
Location Czech Republic CZ
Gabriel
Your dedicated contact
Gabriel H.

Automatic description (AI-Generated)

The Becton Dickinson BD FACSCanto II Flow Cytometer is a sophisticated analytical instrument designed for multi-parameter cellular analysis, suitable for a broad range of research applications. This model features three lasers—488 nm blue, 633 nm red, and 405 nm violet—enabling simultaneous detection of up to 10 colors with 12 detectors for enhanced sensitivity.

Optical capabilities include forward scatter (FSC) detection with a photodiode and side scatter (SSC) detection via a photomultiplier tube (PMT), providing high-resolution measurements essential for detailed cell analysis. The fluorescence detection system employs 10 PMTs arranged in a 5-3-2 configuration across the three lasers, allowing precise differentiation of multiple fluorescent markers.

The fluidics system incorporates the self-contained BD FACSCanto Fluidics Supply Cart with fluidics harness and level sensors for sheath, waste, clean, and shutdown fluids. It operates with a sheath consumption rate of approximately 1.10 L/h during normal operation and less than 1 mL/h in standby mode, ensuring efficient sample processing with minimal carryover (<0.1%). Samples are injected directly into the flow cell, accommodating particle sizes up to 50 µm. The system supports sample flow rates ranging from 10 to 120 µL/min and can acquire data at rates up to 33,000 events per second.

Included with the instrument is a computer equipped with a monitor, keyboard, and mouse running Windows 7 OS. Software provided includes BD FACSDiva 8.0.1 with a license dongle and Clinical Software FACS Suite, facilitating comprehensive data acquisition and analysis.

The instrument appears clean and well-maintained with no visible damage. Notable visible features include an open compartment on the right side revealing internal connectors and cables, coiled tubing and cables attached to the lower section, and a transparent panel at the bottom front that exposes internal fluid containers or filters. These components support the instrument's operational integrity and ease of maintenance.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.

Seller's description

BD FACSCanto II Flow Cytometer
• Multi-parameter analysis, Versatile research applications - 3 lasers, 10 color capability (12 detectors for high sensitivity)
• Self-contained BD FACSCanto Fluidics Supply Cart with Fluidics Harness Fluidics Level Sensors (Sheath, Waste, Clean, Shutdown)
• Computer with (w/ monitor, keyboard, mouse, OS Win7)
o BD FACSDiva 8.0.1software w/ License Dongle
o Clinical Software FACS Suite
• Communication and power cables
• Versatile research applications.

BD FACS Canto II Flow Cytometer Configuration:
Optics:
• (3) Lasers: 488nm Blue / 633nm Red / Violet 405nm
• (10) Colors simultaneously (plus FSC, SSC)
• FSC Detector: Photodiode with 488/10 BP; FSC Resolution: 1.0 um
• SSC Detector: PMT with 488/10 BP; SSC Resolution: 0.5 um
Fluorescence Detectors: 10 PMTs in 5-3-2 configuration
• - 488nm blue laser:
o Channel A (780/60, 735LP)
o Channel B (>670LP,655LP)
o Channel C (610LP)
o Channel D (585/42, 556LP)
o Channel E (530/30, 502LP)
• - 633nm red laser:
o Channel A (730/45, 685LP)
o Channel B (690LP)
o Channel C (660/20)
• - 405nm violet laser:
o Channel A (510/50, 502LP)
o Channel B (450/50)
Fluidics:
• Sheath Consumption: 1.10 L/h normal operation; <1 mL/h standby
• Carryover: <0.1%
• Sample Injection: Directly into flow cell
• Maximum Particle Size: 50 um
• Sample Flow Rate, Min/Mid/Max: 10/ 60/ 120 uL/min
• Sample Acquisition Rate: 33,000 events/second

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.


Frequently Asked Questions (AI-Generated)

  • Is this equipment not in operation at the moment?

  • This equipment is not currently in operation.

  • Is this equipment preserved and disconnected?

  • This equipment is preserved and disconnected.

The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.


Client type Factory – small or medium company
Active since 2025
Offers online 1
Last activity Oct. 20, 2026

Seller's description

BD FACSCanto II Flow Cytometer
• Multi-parameter analysis, Versatile research applications - 3 lasers, 10 color capability (12 detectors for high sensitivity)
• Self-contained BD FACSCanto Fluidics Supply Cart with Fluidics Harness Fluidics Level Sensors (Sheath, Waste, Clean, Shutdown)
• Computer with (w/ monitor, keyboard, mouse, OS Win7)
o BD FACSDiva 8.0.1software w/ License Dongle
o Clinical Software FACS Suite
• Communication and power cables
• Versatile research applications.

BD FACS Canto II Flow Cytometer Configuration:
Optics:
• (3) Lasers: 488nm Blue / 633nm Red / Violet 405nm
• (10) Colors simultaneously (plus FSC, SSC)
• FSC Detector: Photodiode with 488/10 BP; FSC Resolution: 1.0 um
• SSC Detector: PMT with 488/10 BP; SSC Resolution: 0.5 um
Fluorescence Detectors: 10 PMTs in 5-3-2 configuration
• - 488nm blue laser:
o Channel A (780/60, 735LP)
o Channel B (>670LP,655LP)
o Channel C (610LP)
o Channel D (585/42, 556LP)
o Channel E (530/30, 502LP)
• - 633nm red laser:
o Channel A (730/45, 685LP)
o Channel B (690LP)
o Channel C (660/20)
• - 405nm violet laser:
o Channel A (510/50, 502LP)
o Channel B (450/50)
Fluidics:
• Sheath Consumption: 1.10 L/h normal operation; <1 mL/h standby
• Carryover: <0.1%
• Sample Injection: Directly into flow cell
• Maximum Particle Size: 50 um
• Sample Flow Rate, Min/Mid/Max: 10/ 60/ 120 uL/min
• Sample Acquisition Rate: 33,000 events/second

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.


Frequently Asked Questions (AI-Generated)

  • Is this equipment not in operation at the moment?

  • This equipment is not currently in operation.

  • Is this equipment preserved and disconnected?

  • This equipment is preserved and disconnected.

The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.



Automatic description (AI-Generated)

The Becton Dickinson BD FACSCanto II Flow Cytometer is a sophisticated analytical instrument designed for multi-parameter cellular analysis, suitable for a broad range of research applications. This model features three lasers—488 nm blue, 633 nm red, and 405 nm violet—enabling simultaneous detection of up to 10 colors with 12 detectors for enhanced sensitivity.

Optical capabilities include forward scatter (FSC) detection with a photodiode and side scatter (SSC) detection via a photomultiplier tube (PMT), providing high-resolution measurements essential for detailed cell analysis. The fluorescence detection system employs 10 PMTs arranged in a 5-3-2 configuration across the three lasers, allowing precise differentiation of multiple fluorescent markers.

The fluidics system incorporates the self-contained BD FACSCanto Fluidics Supply Cart with fluidics harness and level sensors for sheath, waste, clean, and shutdown fluids. It operates with a sheath consumption rate of approximately 1.10 L/h during normal operation and less than 1 mL/h in standby mode, ensuring efficient sample processing with minimal carryover (<0.1%). Samples are injected directly into the flow cell, accommodating particle sizes up to 50 µm. The system supports sample flow rates ranging from 10 to 120 µL/min and can acquire data at rates up to 33,000 events per second.

Included with the instrument is a computer equipped with a monitor, keyboard, and mouse running Windows 7 OS. Software provided includes BD FACSDiva 8.0.1 with a license dongle and Clinical Software FACS Suite, facilitating comprehensive data acquisition and analysis.

The instrument appears clean and well-maintained with no visible damage. Notable visible features include an open compartment on the right side revealing internal connectors and cables, coiled tubing and cables attached to the lower section, and a transparent panel at the bottom front that exposes internal fluid containers or filters. These components support the instrument's operational integrity and ease of maintenance.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.


About this seller

Client type Factory – small or medium company
Active since 2025
Offers online 1
Last activity Oct. 20, 2026

Here is a selection of similar machines - Becton Dickinson BD FACSCanto II Flow Cytometer

Becton Dickinson BD FACSCanto II flow cytometer