Automatic description (AI-Generated)

This listing features a Gas Turbine Plant equipped with a Vitomax ADHZ • UE 15.0 Boiler, constructed in the 2010s. The system is designed to deliver an electrical power output of 2000 kW. It includes a peak load boiler with a capacity of 16 tons per hour and a waste heat boiler capable of handling 14.5 tons per hour.

The boiler system is divided into four modules, each with specific pressure and temperature ratings:
- Module A (Steam) operates at a pressure of 31.4 bar(g) and a temperature of 465 °C.
- Module B (Water) functions at a pressure of 39.0 bar(g) and a temperature of 120 °C.
- Module C (Condensate) matches Module A's pressure and temperature at 31.4 bar(g) and 465 °C respectively.
- Module D (Gas) operates at a pressure of 16.0 bar(g) with a temperature of 50 °C.

The overall pressure range for the system is from 0 to 31.4 bar(g). Temperature limits are 10 to 238.2 °C for the pressure body and 10 to 298 °C for the combustion chamber. The boiler has a full content volume of 28,700 liters for water and 400 liters for steam.

The medium handled by the boiler includes both water and steam. It features a heated surface area of 575.4 square meters, supporting a maximum steam production rate of 15,000 kg per hour. The maximum net capacity ranges between 58.1 and 69.5 kW.

This equipment is offered in as-is, where-is condition. No additional accessories or components are specified or visible.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.

Seller's description

Type: Gas Turbine Plant / Vitomax ADHZ • UE 15.0 Boiler
Year of Construction: 2010s
Electrical Power: 2000 kW
Peak Load Boiler: 16 t/h
Waste Heat Boiler: 14.5 t/h

Module A – Steam:
- Pressure (PS): 31.4 bar(g)
- Temperature (TS): 465 °C

Module B – Water:
- Pressure (PS): 39.0 bar(g)
- Temperature (TS): 120 °C

Module C – Condensate:
- Pressure (PS): 31.4 bar(g)
- Temperature (TS): 465 °C

Module D – Gas:
- Pressure (PS): 16.0 bar(g)
- Temperature (TS): 50 °C

Pressure (Pmin / Pmax): 0 / 31.4 bar(g)
Temperature (Tmin / Tmax): 10 / 238.2 °C (Pressure Body) / 10 / 298 °C (Combustion Chamber)
Content (Full): 28,700 L / 400 L
Medium: Water / Steam
Heated Surface: 575.4 m²
Max. Steam Production: 15,000 kg/h
Max. Net Capacity: 58.1 / 69.5 kW
Technical Condition: As-is, where-is

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.


Frequently Asked Questions (AI-Generated)

  • What is the reference for this equipment?

  • This equipment has reference 6478.

  • What reference number accompanies this UE Recovery Boiler Kessel?

  • This UE Recovery Boiler Kessel includes reference 6478.

  • What is the reference number for this equipment?

  • This equipment has reference 6478.

  • What is this equipment's Exapro listing name?

  • This equipment is listed on Exapro as UE Recovery Boiler Kessel.

  • What is the Exapro listing URL?

  • This listing provides the URL https://www.exapro.de.com/ue-recovery-boiler-p260602191.

The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.


Client type Machinery dealer
Active since 2023
Offers online 108
Last activity Oct. 26, 2026

Seller's description

Type: Gas Turbine Plant / Vitomax ADHZ • UE 15.0 Boiler
Year of Construction: 2010s
Electrical Power: 2000 kW
Peak Load Boiler: 16 t/h
Waste Heat Boiler: 14.5 t/h

Module A – Steam:
- Pressure (PS): 31.4 bar(g)
- Temperature (TS): 465 °C

Module B – Water:
- Pressure (PS): 39.0 bar(g)
- Temperature (TS): 120 °C

Module C – Condensate:
- Pressure (PS): 31.4 bar(g)
- Temperature (TS): 465 °C

Module D – Gas:
- Pressure (PS): 16.0 bar(g)
- Temperature (TS): 50 °C

Pressure (Pmin / Pmax): 0 / 31.4 bar(g)
Temperature (Tmin / Tmax): 10 / 238.2 °C (Pressure Body) / 10 / 298 °C (Combustion Chamber)
Content (Full): 28,700 L / 400 L
Medium: Water / Steam
Heated Surface: 575.4 m²
Max. Steam Production: 15,000 kg/h
Max. Net Capacity: 58.1 / 69.5 kW
Technical Condition: As-is, where-is

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.


Frequently Asked Questions (AI-Generated)

  • What is the reference for this equipment?

  • This equipment has reference 6478.

  • What reference number accompanies this UE Recovery Boiler Kessel?

  • This UE Recovery Boiler Kessel includes reference 6478.

  • What is the reference number for this equipment?

  • This equipment has reference 6478.

  • What is this equipment's Exapro listing name?

  • This equipment is listed on Exapro as UE Recovery Boiler Kessel.

  • What is the Exapro listing URL?

  • This listing provides the URL https://www.exapro.de.com/ue-recovery-boiler-p260602191.

The following questions and answers are generated using artificial intelligence based on the product information available. They are provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.



Automatic description (AI-Generated)

This listing features a Gas Turbine Plant equipped with a Vitomax ADHZ • UE 15.0 Boiler, constructed in the 2010s. The system is designed to deliver an electrical power output of 2000 kW. It includes a peak load boiler with a capacity of 16 tons per hour and a waste heat boiler capable of handling 14.5 tons per hour.

The boiler system is divided into four modules, each with specific pressure and temperature ratings:
- Module A (Steam) operates at a pressure of 31.4 bar(g) and a temperature of 465 °C.
- Module B (Water) functions at a pressure of 39.0 bar(g) and a temperature of 120 °C.
- Module C (Condensate) matches Module A's pressure and temperature at 31.4 bar(g) and 465 °C respectively.
- Module D (Gas) operates at a pressure of 16.0 bar(g) with a temperature of 50 °C.

The overall pressure range for the system is from 0 to 31.4 bar(g). Temperature limits are 10 to 238.2 °C for the pressure body and 10 to 298 °C for the combustion chamber. The boiler has a full content volume of 28,700 liters for water and 400 liters for steam.

The medium handled by the boiler includes both water and steam. It features a heated surface area of 575.4 square meters, supporting a maximum steam production rate of 15,000 kg per hour. The maximum net capacity ranges between 58.1 and 69.5 kW.

This equipment is offered in as-is, where-is condition. No additional accessories or components are specified or visible.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.


About this seller

Client type Machinery dealer
Active since 2023
Offers online 108
Last activity Oct. 26, 2026

Here is a selection of similar machines - UE Recovery Boiler

UE Recovery Boiler Industrial boiler