Manufacturer: Optima
Model: MEDICON ImmuCoat
Technical condition: Good
Listing status: Visible
Overview
Optima MEDICON ImmuCoat is a complete production and packaging line intended for manufacture of 96‑well microtiter plates for ELISA test kits. The line integrates plate handling, deionization, coding, multi‑step coating and verification, incubation, washing/aspiration, drying and final packaging into a continuous process. The system description below follows the documented process flow and included modules.
Process steps and modules
1. Feeding and preparation: Microtiter plates are automatically retrieved from destackers and transferred to the transport system. 2. Deionization: Plates are deionized to reduce static charges and support uniform coating. 3. Coding: Each plate is assigned a unique serial number. 4. Coating: Precision dispensing of biological components into each well of a 96‑well plate. Documented dispensing range is 0–500 µl per well with a dosing rate of 0–30,000 µl/s per well. An automatic level verification unit (Level Verification Ultrasonic V2 Y) with an 8‑channel ultrasonic sensor is included for level checking. 5. Long‑term incubation: Two long‑term incubators are included with a combined capacity of approximately 5,100 microtiter plates. 6. Aspiration and washing module: Plate washing and aspiration are provided, followed by a second dispensing unit with level verification. 7. Short‑term incubator: A short‑term incubator (documented as without climate control) is part of the line. 8. Incubator with drying function: A separate incubator with drying capability is included. 9. Packaging: A packaging machine packs microtiter plates into pre‑made bags; desiccant sachets can be added and bag labeling is available as an option.
System configuration and throughput
The system comprises two base stations for 12 plates and one base station for 6 plates. Documented throughput is up to 800 plates per hour.
Notes
All specifications above are taken from the provided product listing. No additional components, testing status, hours run, or service history are claimed beyond the listed information.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
Manufacturer: Optima
Model: MEDICON ImmuCoat
Technical condition: Good
Listing status: Visible
Description: Optima MEDICON ImmuCoat complete production and packaging line for ELISA test kits, consisting of an Optima MEDICON ImmuCoat coating system for the production of 96-well microtiter plates for ELISA kits. Operation and process steps: 1. Feeding and preparation: Microtiter plates are automatically retrieved and transferred to the transport system. 2. Deionization: Plates are deionized to eliminate static charges and ensure uniform coating. 3. Coding: Each plate is assigned a unique serial number. 4. Coating: The system precisely dispenses biological components into the wells of the 96-well plate (dispensing volume 0–500 µl per well, dosing rate 0–30,000 µl/s per well), followed by automatic level verification (Level Verification Ultrasonic V2 Y with an 8-channel ultrasonic sensor). 5. 2 long-term incubators with a total capacity of approximately 5,100 microtiter plates. 6. Aspiration and washing module for the microtiter plates, followed by a second dispensing unit and level verification. 7. Short-term incubator (without climate control). 8. 1 incubator with a drying function. 9. Packaging machine for packing microtiter plates into pre-made bags; desiccant bags can be added and the bags labeled as an option. The system consists of two base stations for 12 plates and one base station for 6 plates. The system’s throughput is up to 800 plates per hour.
Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.
| Client type | Machinery dealer |
| Active since | 2020 |
| Offers online | 110 |
| Last activity | Oct. 26, 2026 |
Manufacturer: Optima
Model: MEDICON ImmuCoat
Technical condition: Good
Listing status: Visible
Description: Optima MEDICON ImmuCoat complete production and packaging line for ELISA test kits, consisting of an Optima MEDICON ImmuCoat coating system for the production of 96-well microtiter plates for ELISA kits. Operation and process steps: 1. Feeding and preparation: Microtiter plates are automatically retrieved and transferred to the transport system. 2. Deionization: Plates are deionized to eliminate static charges and ensure uniform coating. 3. Coding: Each plate is assigned a unique serial number. 4. Coating: The system precisely dispenses biological components into the wells of the 96-well plate (dispensing volume 0–500 µl per well, dosing rate 0–30,000 µl/s per well), followed by automatic level verification (Level Verification Ultrasonic V2 Y with an 8-channel ultrasonic sensor). 5. 2 long-term incubators with a total capacity of approximately 5,100 microtiter plates. 6. Aspiration and washing module for the microtiter plates, followed by a second dispensing unit and level verification. 7. Short-term incubator (without climate control). 8. 1 incubator with a drying function. 9. Packaging machine for packing microtiter plates into pre-made bags; desiccant bags can be added and the bags labeled as an option. The system consists of two base stations for 12 plates and one base station for 6 plates. The system’s throughput is up to 800 plates per hour.
Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.
| Category | Complete lines - Packaging production |
| worked hours | |
| hours under power | |
| state | good |
| At local norms | yes |
| status | visible |
| Datasheet | Optima MEDICON ImmuCoat |
| Last availability date | 23/10/2026 |
| Product id | P260903428 |
| Language |
Manufacturer: Optima
Model: MEDICON ImmuCoat
Technical condition: Good
Listing status: Visible
Overview
Optima MEDICON ImmuCoat is a complete production and packaging line intended for manufacture of 96‑well microtiter plates for ELISA test kits. The line integrates plate handling, deionization, coding, multi‑step coating and verification, incubation, washing/aspiration, drying and final packaging into a continuous process. The system description below follows the documented process flow and included modules.
Process steps and modules
1. Feeding and preparation: Microtiter plates are automatically retrieved from destackers and transferred to the transport system. 2. Deionization: Plates are deionized to reduce static charges and support uniform coating. 3. Coding: Each plate is assigned a unique serial number. 4. Coating: Precision dispensing of biological components into each well of a 96‑well plate. Documented dispensing range is 0–500 µl per well with a dosing rate of 0–30,000 µl/s per well. An automatic level verification unit (Level Verification Ultrasonic V2 Y) with an 8‑channel ultrasonic sensor is included for level checking. 5. Long‑term incubation: Two long‑term incubators are included with a combined capacity of approximately 5,100 microtiter plates. 6. Aspiration and washing module: Plate washing and aspiration are provided, followed by a second dispensing unit with level verification. 7. Short‑term incubator: A short‑term incubator (documented as without climate control) is part of the line. 8. Incubator with drying function: A separate incubator with drying capability is included. 9. Packaging: A packaging machine packs microtiter plates into pre‑made bags; desiccant sachets can be added and bag labeling is available as an option.
System configuration and throughput
The system comprises two base stations for 12 plates and one base station for 6 plates. Documented throughput is up to 800 plates per hour.
Notes
All specifications above are taken from the provided product listing. No additional components, testing status, hours run, or service history are claimed beyond the listed information.