Contact us to receive an offer.
| Category | Energy - Generator sets |
| Alternator manufacturer | |
| Alternator model | |
| Frequency | 50Hz 1500 t/min |
| worked hours | |
| hours under power | |
| state | as-is, where-is |
| At local norms | --------- |
| status | |
| Datasheet | Leroy Somer LSA 44.1L6 AREP |
| Last availability date | 21/10/2026 |
| Product id | P261013113 |
| Language |
Generator / emergency generator equipped with a Leroy-Somer alternator, type LSA 44.1L6 AREP. The available product information gives a year of manufacture of 1993 and states a continuous-duty output of 80 kW / 100 kVA. It is specified for three-phase operation at 400 V, with a frequency of 50 Hz at 1500 rpm. The listed current is approximately 144.3 A.
The details above describe the generator and its stated electrical ratings. The Leroy-Somer manufacturer and LSA 44.1L6 AREP type designation are provided for identification. The output, voltage, phase, frequency, speed and current information may be useful when assessing whether the unit’s stated configuration matches an intended installation or replacement requirement. No additional technical specifications are provided in the available description.
No further information is given about the generator’s operating condition, maintenance history, testing, included accessories or other components. These points should not be assumed from the product details listed here. The description does not state any additional features or performance claims beyond the manufacturer, type, year and electrical information above.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
Generator / Emergency Generator
Manufacturer: Leroy-Somer
Type: LSA 44.1L6 AREP
Year of Manufacture: 1993
Continuous output (Continuous Duty): 80 kW / 100 kVA
Voltage: 400 V (three-phase)
Frequency & speed: 50 Hz at 1500 rpm
Current: approx. 144.3 A
Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.
| Client type | Machinery dealer |
| Active since | 2017 |
| Offers online | 115 |
| Last activity | Oct. 23, 2026 |
Generator / Emergency Generator
Manufacturer: Leroy-Somer
Type: LSA 44.1L6 AREP
Year of Manufacture: 1993
Continuous output (Continuous Duty): 80 kW / 100 kVA
Voltage: 400 V (three-phase)
Frequency & speed: 50 Hz at 1500 rpm
Current: approx. 144.3 A
Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.
| Category | Energy - Generator sets |
| Alternator manufacturer | |
| Alternator model | |
| Frequency | 50Hz 1500 t/min |
| worked hours | |
| hours under power | |
| state | as-is, where-is |
| At local norms | --------- |
| status | |
| Datasheet | Leroy Somer LSA 44.1L6 AREP |
| Last availability date | 21/10/2026 |
| Product id | P261013113 |
| Language |
Generator / emergency generator equipped with a Leroy-Somer alternator, type LSA 44.1L6 AREP. The available product information gives a year of manufacture of 1993 and states a continuous-duty output of 80 kW / 100 kVA. It is specified for three-phase operation at 400 V, with a frequency of 50 Hz at 1500 rpm. The listed current is approximately 144.3 A.
The details above describe the generator and its stated electrical ratings. The Leroy-Somer manufacturer and LSA 44.1L6 AREP type designation are provided for identification. The output, voltage, phase, frequency, speed and current information may be useful when assessing whether the unit’s stated configuration matches an intended installation or replacement requirement. No additional technical specifications are provided in the available description.
No further information is given about the generator’s operating condition, maintenance history, testing, included accessories or other components. These points should not be assumed from the product details listed here. The description does not state any additional features or performance claims beyond the manufacturer, type, year and electrical information above.
The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.
| Client type | Machinery dealer |
| Active since | 2017 |
| Offers online | 115 |
| Last activity | Oct. 23, 2026 |