Manufacturer Gettinge
Model GE 91413 ARC-2
Year
Location Germany DE
Jérémie
Your dedicated contact
Jérémie R.

Automatic description (AI-Generated)

Manufacturer and model: Göttinge (Gettinge) GE 91413 ARC-2. Type: Pass-through autoclave in a two-door pass-through design with automatic, horizontally sliding doors and a fitted cross-contamination barrier. Current state and condition: Listed as visible; technical condition reported as Good.

Design and chamber: Chamber external dimensions (W x H x D) 950 x 1450 x 1350 mm with usable chamber space of 920 x 1450 x 1350 mm. Chamber volume is specified as approximately 1859 litres. Rated chamber pressure range is -1.0 to +3.0 bar and the design temperature is 143.6 °C.

Controls and documentation: Machine control system is Siemens S7-300. Operator interface is a Siemens MP277 touch control panel. A colour laser printer for programme documentation is specified as part of the unit.

Electrical and mechanical data: Electrical supply specified as 230/400 V, 50 Hz, 3-phase. Overall machine dimensions (W x D x H) are approximately 3100 x 2350 x 1710 mm. Unladen weight is approximately 2450 kg.

Usage history: Previously used for processing metal format parts, dosing pumps, stoppers, filters, clothing and similar items.

Notes for prospective buyers: This description consolidates the technical and configuration details provided for this GE 91413 ARC-2 pass-through autoclave. Included items listed here are those specified with the unit (control system, touch panel, documentation printer and cross-contamination barrier). No additional visible accessories or external items are asserted beyond these specifications.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.

Seller's description

Manufacturer: Gettinge
Model: GE 91413 ARC-2
Technical condition: Good
State: Visible
Autoclave type: Pass-through autoclave
Design: Two-door pass-through with automatic, horizontally sliding door
Cross-contamination barrier: Fitted
Usage history: Previously used for metal format parts, dosing pumps, stoppers, filters, clothing, etc.
Chamber dimensions (W x H x D): 950 x 1450 x 1350 mm
Usable chamber space (W x H x D): 920 x 1450 x 1350 mm
Chamber volume: 1859 litres
Chamber pressure: -1.0 to +3.0 bar
Design temperature: 143.6 °C
Control system: Siemens S7-300
Touch control panel: Siemens MP 277
Documentation printer: Colour laser printer for programme documentation
Electrical supply: 230/400 V/50 Hz/3-phase
Overall dimensions (W x D x H): 3100 x 2350 x 1710 mm
Weight: 2450 kg

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.


Client type Machinery dealer
Active since 2020
Offers online 109
Last activity Oct. 30, 2026

Seller's description

Manufacturer: Gettinge
Model: GE 91413 ARC-2
Technical condition: Good
State: Visible
Autoclave type: Pass-through autoclave
Design: Two-door pass-through with automatic, horizontally sliding door
Cross-contamination barrier: Fitted
Usage history: Previously used for metal format parts, dosing pumps, stoppers, filters, clothing, etc.
Chamber dimensions (W x H x D): 950 x 1450 x 1350 mm
Usable chamber space (W x H x D): 920 x 1450 x 1350 mm
Chamber volume: 1859 litres
Chamber pressure: -1.0 to +3.0 bar
Design temperature: 143.6 °C
Control system: Siemens S7-300
Touch control panel: Siemens MP 277
Documentation printer: Colour laser printer for programme documentation
Electrical supply: 230/400 V/50 Hz/3-phase
Overall dimensions (W x D x H): 3100 x 2350 x 1710 mm
Weight: 2450 kg

Please note that this description may have been translated or optimized with artificial intelligence (AI) automatically. The information of this classified ad are only indicative. We recommend to check the details with the seller before a purchase.



Automatic description (AI-Generated)

Manufacturer and model: Göttinge (Gettinge) GE 91413 ARC-2. Type: Pass-through autoclave in a two-door pass-through design with automatic, horizontally sliding doors and a fitted cross-contamination barrier. Current state and condition: Listed as visible; technical condition reported as Good.

Design and chamber: Chamber external dimensions (W x H x D) 950 x 1450 x 1350 mm with usable chamber space of 920 x 1450 x 1350 mm. Chamber volume is specified as approximately 1859 litres. Rated chamber pressure range is -1.0 to +3.0 bar and the design temperature is 143.6 °C.

Controls and documentation: Machine control system is Siemens S7-300. Operator interface is a Siemens MP277 touch control panel. A colour laser printer for programme documentation is specified as part of the unit.

Electrical and mechanical data: Electrical supply specified as 230/400 V, 50 Hz, 3-phase. Overall machine dimensions (W x D x H) are approximately 3100 x 2350 x 1710 mm. Unladen weight is approximately 2450 kg.

Usage history: Previously used for processing metal format parts, dosing pumps, stoppers, filters, clothing and similar items.

Notes for prospective buyers: This description consolidates the technical and configuration details provided for this GE 91413 ARC-2 pass-through autoclave. Included items listed here are those specified with the unit (control system, touch panel, documentation printer and cross-contamination barrier). No additional visible accessories or external items are asserted beyond these specifications.

The following description has been generated using artificial intelligence based on the product information available. It is provided for guidance only and may not reflect all specifications or conditions. Please contact us if you need precise or confirmed details.


About this seller

Client type Machinery dealer
Active since 2020
Offers online 109
Last activity Oct. 30, 2026

Here is a selection of similar machines - Gettinge GE 91413 ARC-2


Used Autoclaves for Sale

Autoclaves and sterilizers are critical for pharmaceutical production, laboratory work, and food processing. Used units on Exapro range from compact benchtop models to large industrial sterilization chambers. Filter by chamber volume, temperature range, and application.

Gettinge GE 91413 ARC-2 pass-through autoclave